This decrease in memory utilization is. The Cisco 2901 and 2911 have 2 PVDM slots each, the Cisco 2921 and 2951 have 3 PVDM slots each, and the Cisco 3925 and 3945 have 4 PVDM slots each. Activity 3. Data diperbaharui pada 23/11/2023. A Cisco cBR-8 CCAP line card has two downstream PHY modules. In Stock. 8 W. $707. Product overview. Data Sheets. 11n access point which is backwards compatible with IEEE 802. Refer to Cisco Technical Tips Conventions for more information on document conventions. ===============. For example you have a telecommunications room with ten (10) Cisco Catalyst 2960X-48FPD-L which according to Cisco draws a maximum of 66. Ports 11-15 VLAN 999. Return to TopCISCO2901-V/K9 Datasheet. Platform Support . We have 5 Cisco Cisco 3900 series manuals available for free PDF download: Installation Manual, Manual, Datasheet Cisco Cisco 3900 series Installation Manual (220 pages) Hardware Installation GuideThe Cisco 8000 Series combines the revolutionary Cisco Silicon One ™, IOS XR ® software, and a set of clean sheet chassis to deliver a breakthrough in high-performance routers. PC client connected to port 7, which is configured as VLAN 200. 60 Watts w/ 2 TCC2, 2 XC10G, 1 AIC-I, 2 OC192 LR/STM64 LH 1550, 10 E100T-G Power Consumption per Card. Some key features include: Table 1 shows a list of all din-rail power supplies. Table A-2 650 W AC Power Supply Specifications. Product Description. I have this problem too. The Cisco 113x ISR models introduced 802. 89. An optional DC power supply that extends possible deployment environments such as central offices and industrial environments will be available in the future. Motherboard Components Power consumption = 74. The 4-port Cisco EtherSwitch HWIC has four 10/100 switched Ethernet ports, with options for inline power support on all four ports. This table lists them along with their characteristics: Table 1. This reduces the maximum. The unit has no SYS led operation or fan operation. Product Details. Options. 2 or 4 fixed 1 Gigabit Ethernet Small Form-Factor Pluggable (SFP) uplinks or 4 fixed 10 Gigabit Ethernet SFP+ uplinks. Cisco EnergyWise technology will be supported in the future. The first downstream PHY module has port number 0 through port number 3. PS Type Watts A @42V Status Status State. The compact, high-density Cisco 1100 Terminal Services Gateway (C1100. Module and Router Power Consumption. Cisco 1861 and Cisco 2800, 3800, 2900, 3900, and 3900E Series Integrated Services Router Interoperability with Cisco Unified Communications Manager Data Sheet. They occupy 242,000 square feet, about the size of four American football fields. The end points communicate with the power management station through Cisco devices, such as the Cisco 800 series routers,. on the 12k I could batter in 10gig ports - do you think a chassis full of 10g blades will run the same power as a chassis. USB ports. The main aim is to set an APs transmit power to its optimal value. 3af Power over Ethernet (PoE) and Cisco Enhanced. Setup the RM 5400 Modem where you can get at least 2 Signal Strength lights are lit 5. Toggle power switch off/on to restart device. Live power consumption and budgeting statistics Active PoE ports Per port live PoE statistics 4 Cisco Systems Inc 50 erry A rancois lvd San rancisco CA 415 (415) 432-100 sales@meraki. 6 W. 0 WPower consumption = NM/SM slot 1 3. 10. These devices offer 4-GB DRAM/8-GB flash and 8-GB DRAM/16-GB flash options. Cisco ASR 9001. 3 through the router. 3 W NM/SM slot 1 Power consumption = 27. We have 6 Cisco Cisco 2900 series manuals available for free PDF download: Installation Manual, Manual, Datasheet. Summary of Contents of data sheet for Cisco 3825 CISCO3825. So I am trying to access a 2901/K9 ISR through the USB console port. Number of IP-to-IP Calls per Platform. Move around up to 25 feet from the Router if necessary to get 2 signals. This can be required in a scenario where you use third party IP phones that draw too much PoE. bin" cisco WS-C3560V2-48TS (PowerPC405) processor (revision P0) with. Another method used by many industry professionals is to compare solution power consumption in the idle state. Cisco IOS ® Software Release 15. Ports 1-5 VLAN 100. Cisco 2901 router can i use Ethernet Switch rather then Ethernet Routed-Port for ITSP SIP Connectivity Go to solution. 000. It allows network security, unified communications, and fully integrated power distribution to support modules of 802. Hello community! I have been trying to understand the table shown in the attached screenshot of the power consumption of this switch ( C9200-48P-E) , if you could please help, thank you. 9. Cisco 860 Series delivers features, including firewall, IPSec VPNs, and WLANs, at broadband speeds to small offices. You can control the maximum power consumption on a server through power capping, as well as manage the power allocation in the Cisco UCS Manager for blade servers, UCS C220 and C240 M4 rack servers, UCS Mini, and mixed UCS domains. The ip default-network command allows you to configure robustness into the selection of a gateway of last resort. It's available via the provided link. Scroll to the far right for power button. Cisco Small Business 110 Series Unmanaged Switches Data Sheet - Affordable 10/100/1000-Mbps speeds for even the most bandwidth-hungry applications; 5- to 24-port models that are desktop or rack mountable; Power over Ethernet models to provide power to IP phones, access points, and other devices; Works right out of the box: plug. I did the following test to try figure out the consumption from the power grid. 13 A for operation in the UK . Each of the AC power inputs requires a separate dedicated branch circuit. 66. Each downstream PHY module consumes approximately 70W of. Labels: Labels:power to the modules based on the time of day. Each module has DC-to-DC power supplies that convert the 42 VDC into +2. . They provide high availability during power failure through an external universal power. Business benefits of ISR 1000 Series. Note: To access this Tool, you requrie Privileged Level Access. 750W. Cisco 2901: CISCO3945E/K9: Cisco 3945 with 4 onboard GE, C3900-SPE250/K9, 3 EHWIC slots, 3. The average power consumed by the Cisco UCS chassis in the idle state was 43W less than the equivalently configured Dell PowerEdge enclosure: a difference of 5. If configured with dual power supplies or an Redundant power supplies (RPS), the power supplies are hot swappable. Page 1: CISCO 3800 SERIES INTEGRATED SERVICES ROUTERS DATA SHEET CISCO 3800 SERIES INTEGRATED SERVICES ROUTERS CISCO 3825 AND CISCO 3845 Cisco Systems®, Inc. SUMMARY STEPS. English; Español;. AC input voltage:. 4431 vs. -division multiplexing (TDM) interconnections, and fully integrated power distribution to modules supporting 802. saving running config) and got corrupted or erased;As shown in Table 2, the power consumption varies by switch. Product overview. Cisco EnergyWise technology will be supported in the future. pewarski. (Figure 1): the Cisco 2901, 2911, 2921, and 2951 Integrated Services Routers. For the planned switches, no one can provide a ball-park figure because there are many unknowns: What line cards are installed?Cisco 2921 Configuration Manual (409 pages) Cisco 3900 Series, Cisco 2900 Series, Cisco 1900 Series. Module and Router Power Consumption 1-22 Fans, Ventilation, and Airflow 1. Cisco Power Supply. 3 VDC, and +5 VDC to power the module. The Cisco Power Calculator provides BTU information for each of these cards, as well as the Fan (WS-C6506-E Fan). Cisco Nexus 3132Q, 3132Q-X, and 3132Q-XL Switches Data Sheet 06/Jun/2018. Cisco Business Edition 6000 Solutions (DOCX - 772 KB) Cisco Business Edition 6000 - Learn product details such as features and benefits, as well as hardware and software specifications. Muhammad Talha. The Cisco 2900 series offers intelligent power management and allows the customer to control power to the modules based on the time of day. With the AS_PATH filters applied to inbound updates, the size of the BGP routing table is reduced to 31,667 routes, and the memory consumption is approximately 28 MB. Maximum Number of Simultaneous Calls (Flow-Through) Cisco 3945E. 1. Input current: 1. Table 2 gives information about total PoE power output. Figure 5-24 Lifting the 2901 Power Supply In or Out Step 6 Insert the replacement power supply into the chassis. Hostname#show environment table SYSTEM POWER SUPPLY STATUS ===== Internal Power Supply Type: AC Internal Power Supply 12V Output Status: Normal External Redundant Power Supply is absent or powered. 8 W Total System Power consumption is: 82. Price Alert. Solved: I have c1941 with HWIC-4ESW + ILPM-4, power supply has sign POE. Total System Power consumption is: 45. Cisco EnergyWise technology will be supported in. 100% traffic . Remember to add your inline power of Access points, IP phones or cameras. Redundant power supply. I have problem with power consumption of switch Cisco Catalyst 2960S-48TS-L. 0 compliant. System Power Consumption. I used the cisco power consumption tool to determine if these AP's which are mgig capable will be able to work in our existing environment - we currently have 3560X and 3650. So we know the waste heat of the power supplies and. Input-Voltage Range and Frequency. *The product data above is provided by Icecat. 2 Power consumption values for the power consumed internally by the switch at 120 VAC 60 Hz. Cryptographic. Power supply configuration . The 8000 Series comprises a full range of feature-rich, highly scalable, deep-buffered, on-chip High Bandwidth Memory (HBM) and 400 Gigabit Ethernet (GbE). would like to recall the message, " [WAN, Routing and Switching] New message: "1941 PoE" ". (Figure 1): the Cisco 2901, 2911, 2921, and 2951 Integrated Services Routers. PWR-3900-AC/2. The information is based on the rating of the power supply (maximum) and does not reflect the actual measured consumption numbers. Cisco Business Edition 6000 Solutions 28/Feb/2023. The Cisco Power Calculator provides BTU information for each of these cards, as well as the Fan (WS-C6506-E Fan). Cryptographic Accelerator. 23 to 122° F (–5° to 50°C) for. Cisco 1941W ISR. Never install an AC power module and a DC power module in the same chassis. LED goes off if the AC power fails or is disconnected. The modules have their own processors, storage, network interfaces, and memory that operate independently of the host router resources. Services integration and modularity on a single platform performing multiple functions optimizes raw-materials consumption and energy usage. Cisco Catalyst 2960-Plus 48PST-L . com 6 Humidity 5 to 95% RH Altitude 15,000 ft (4,570m) Regulatory Compliance Safety UL 60950-1 CAN/CSA C22. #sh power inline PowerSupply SlotNum. 412. An integrated stateful and application inspection firewall provides network perimeter security. In a PoE scenario, a significant amount of this power is being distributed to PoE devices, and this heat is. 3af-compliant PoE, Cisco ePoE, and Cisco Inline Power) to optional integrated switch modules. Manuals and User Guides for Cisco 2911. 5 to 200 Gbps. The router provides an end-to-end communication network that enables increased power grid efficiency and reliability, reduced energy consumption, and reduced greenhouse gas emissions. A minimum of 3788 AC watts should be set for each chassis. Cisco 3945 Configuration Manual (409 pages) Cisco 3900 Series, Cisco 2900 Series, Cisco 1900 Series. Page 18 Replacing Power Supplies and Redundant Power Supplies 5-28 Replacing the Cisco 2901 Router Power Supply 5-30 Replacing the Cisco 2911 Router Power Supply 5-32 Installing and Removing the Cisco. 7 W. Based on an x86 CPU, the Cisco Catalyst 9500 Series is Cisco’s lead purpose-built fixed core and aggregation enterprise switching platform, built for security,. Cisco 4000 Series Integrated Services Routers: Architecture for Branch-Office Agility (PDF - 971 KB) Miercom Performance Analysis: Cisco 4000 Series ISRs (PDF - 878 KB) 4351 Integrated Services Router: Access product specifications, documents, downloads, Visio stencils, product images, and community content. The Cisco. After power is applied to. The Cisco ® 1100 Terminal Services Gateway provides up to 72 asynchronous ports on a single-rack-unit form factor, supporting up to 24 Layer 2 switch ports, LTE Advanced 3. Muhammad Talha. 8 Amps (about 23W) – show environment reports a lot higher (38W), I am. The CSACS-1121 features include:You can control the maximum power consumption on a server through power capping, as well as manage the power allocation in the Cisco UCS Manager for blade servers, UCS C220 and C240 M4 /M5, and C480 M5 / C480 M5. Cisco 3925/3945 AC Power Supply (Secondary PS) Service Category. 2. 4 • Services integration and modularity on a single platform performing multiple functions, optimizes raw materials consumption and energy usage. • Integration of Content Networking and Branch—Office Routing-With the integration of an optional Content Engine Network Module with branch-office routing, Cisco offers the industry's first and only router. 0 WPower. It is not possible to show the live power consumption via IOS. Page 182: Replacing The Cisco 2901 Router Power Supply Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Cisco 2901 AC Power SupplyPower consumption. Manuals and User Guides for Cisco Cisco 2900 series. That number is the maximum watts the power supply can take. Cisco EnergyWise is an energy management architecture designed to measure power consumption and optimize power usage, resulting in effective delivery of power across the enterprise. 0(1)MInformation About Reducing Power Consumption. White Papers. consumption) (power supply rated for 540W capacity) 135W 135W 30W Redundant power supply (RPS) Optional integrated RPS External UPS External. In this example, I will be installing a WS-X6816-10G-2TXL, three WS-6848-SFP-2TXL, a WS-X6848-TX-2TXL and the sup is a VS-S26-10G-XL. Table 1 lists the features and corresponding feature licenses that provide entitlement for Cisco 1900, 2900, and 3900 Series Integrated Services Routers. The Cisco® Power Calculator enables you to calculate the power supply requirements for a specific Power over Ethernet (PoE) configuration. Secure Key. Value . 750W. In a Cisco EnergyWise network,. It is a slim 1 RU form factor saving rack space. Cisco Business Edition 6000 Solutions 28/Feb/2023. Four integrated EHWIC slots on the Cisco 2901, 2911, 2921, and 2951 allow for more flexible. Cisco 880 Series Router performance allows customers to take advantage of broadband network speeds while running secure, concurrent data, voice, video, and wireless services. On the Cisco 2911, 2921,. 8 WPower consumption = ISM 0. The Cisco Power Calculator supports the following Cisco. Sheshu. Would anyone be able to tell me what the total power consumption would be on a fully populated server? Kind regards BradleyMarksWhen the BGP router receives its neighbors' full BGP routing table (98,410 routes), the router consumes approximately 71 MB. Spanning tree is disabled everywhere There is no trunking and VTP is set to the default, meaning server mode on. comSince in your case config-register ix 0x2102 and was not changed, the problem should be with NVRAM. The phone offers easy-to-use and intuitive arrangement of lines, keys, and calls. The Cisco 2901 ISR has an internal power supply, which requires removing the cover for replacement. Cisco 2901 router Fan issue Go to solution. it depends on what cards you install. 42 Amps @ 42V) system power used = 2253. Connect the Power Supply and turn the power on. Enthusiast Options. 2 2. The Catalyst 8200 Series Edge Platforms are the evolution of the Cisco 4300 series Integrated Services Router (ISR) and are designed for Secure Access Service Edge (SASE), Software-Defined WAN (SD-WAN), and 5G-based architectures. Four integrated EHWIC slots on the Cisco 2901, 2911, 2921, and 2951 allow for more flexible configurations. Key features include:. 96 Amps @ 42V) Power-Capacity PS-Fan Output Oper. The Cisco 2901 Integrated Services Router (ISR) delivers highly secure data, voice, video, and application services for small offices. 4W per port. Power Supplies. The second power supply can provide redundancy or additional power to PoE+ ports as needed. The 4000 Series contains five platforms: the 4451, 4431, 4351, 4331, and 4321 ISRs. i. The Cisco® Catalyst® 9500 Series switches are the next generation of enterprise-class core and aggregation layer switches, supporting full programmability and serviceability. increasing the total power. • Three onboard Gigabit Ethernet (copper or optical) or Fast Ethernet ports. The module power values are based on 42 VDC. The device tracks its power budget (the amount of power available on the device for PoE). 4 release the minimum with power capping is 2 PSUs. Get Discount Bulk Quote & Project Inquiry Início / Sem categoria / WS-C2960X-24TS-L WS-C2960X-24TS-L Switch Cisco 24 Portas Gigabit Gerenciavel Cisco Catalyst 2960X. 47. Cisco IOS Software Release 12. In this case if the cusotmer have this lic at their brand office so they need to buy or how. We purchased new AP's 9120AXi and 9120AXE's. Cisco 1900 Series Integrated Services Routers - Learn product details such as features and benefits, as well as. I have a 2811 and I want to k now what power it will be consuming. 04-13-2011 09:35 AM. Cisco Business Edition 6000 CSR 10. The Cisco 2900 Series is designed to consolidate the functions of many. Cisco WS-C2950-24 Pdf User Manuals. Additional PoE features include the following: Per-port power consumption control allows you to specify a maximum power setting on an individual port. The following software feature is documented in this guide: • Temperature and Voltage Monitoring (TVM) Temperature and Voltage Monitoring (TVM) Temperature and Voltage Monitoring (TVM) is a software feature that provides support for monitoring the router operating temperature and the router. Cisco Redundant Power System 2300 and blower, no power supply . The following table lists the power consumption specifications for a fully configured chassis. 06 Watts (19. Cisco 1941W Integrated Services Router . Beginner. Figure 1-3 Back Panel LEDs of Cisco 2901 Router Cisco 2911 Chassis Figure 1-4— Front panelThis feature enables the end user to monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage. Network modules spec is a little higher at 25 Watts. Power Consumption . Cisco Catalyst 3850 Series Switches, designed and engineered by Cisco, provide optimum power-saving, EEE (on RJ45 ports), low-power operations for industry best-in-class power management and power consumption capabilities. The 42 VDC is independent of the power supply’s input voltage, either 110 VAC or 220 VAC. Power is distributed to each slot in the chassis from the power supply’s 42 VDC output. 10% traffic . Hence, if there is a show or debug command that can be done to see real-time data or data averaged over a certain period of time on the power consumption of a POE device that is connected to a Cisco switch. 51. Power consumption (typical) 40 W. The Cisco 2900 Series offers intelligent power management and allows the customer to control power to the modules based on the time of day. Data Sheets. The results show output current, output power, and system heat dissipation. The Cisco Nexus 3524-X and 3524 - XL are powered by the data-center-class Cisco NX-OS operating system. Statement 1029 To replace the power supply in a Cisco 2901 router, perform the following steps. Table of Contents. I looked at the data sheet for the 2821 and it says 3A for the 110V under the row AC Input Current Would that be accurate if I did. 2 Fans operate in a 3+1 redundant configuration where the system will continue to function with only 3 operational fans. Fully integrated power distribution to modules supporting 802. 02-Nov-2015. Stacking. The routers contain both hardware and software. 3af client connected 17 17 Fiber user as backhaul 1 1 Total Power Consumption Total Power Consumption When DC Powered. Cisco 1109-2PLTE with fixed CAT4 LTE (Available late October, 2018) Business Benefits Table 1. Power to ISM slots can be managed by extensions similar to the Cisco EnergyWise framework, so your organization can reduce energy consumption in your network infrastructure. Power Consumption in Power Save Mode (in Watts): We want to use 'In Power Save mode', so the backlight will be turned off and when we pick up the receiver or do any activity then. 47. Total System Power consumption is: 46. system power total = 5771. 168. Secure Voice on Cisco Integrated Services Routers. A Cisco cBR-8 CCAP line card has two downstream PHY modules. Cisco EnergyWise ® support: Lower per-port power consumption is supported on the VG350. 5 VDC, +3. system power total = 2771. Cisco IOS Universal: Power Device: Internal power supply: RAM: 512 MB (installed) / 2 GB (max) - DDR2 SDRAM:Maximum PoE device power capacity with PoE power supply; 80 W. Cisco 2901 datasheet power consumption Cisco 2901 Integrated Router Service (ISR) offers very secure data, audio, video, and app services for small offices. BLNK-RPS2300= Spare bay insert for Cisco Redundant Power System 2300 . yes, you should be able to ping IP address or hostname from your 2901. Input-Voltage Range and Frequency. Cisco 2901 specifications, prices, product images and videos. Actual Power Consumption when idle (in Watts): 3. 5 Figure B-6 CAB-9K10A-IT Power Cord, 250 VAC 10 A CEI 23-16 Plug Italy 8. 10. An optional external power chassis provides in-line power to IP Phones and to Aironet 802. 6 W. Cisco Catalyst 3850 Series Switches, designed and engineered by Cisco, provide optimum power-saving, EEE (on RJ45 ports), low-power operations for industry best-in-class power management and power consumption capabilities. Get Discount Bulk Quote & Project Inquiry Cisco Integrated Services Routers Generation 2 (ISR G2) offer data functionality through Gigabit Ethernet ports and security functionality with. It shows up correctly in device manager (See attached image). 9. The Cisco ISR G2 provides a highly secure and reliable platform for scalable multi-service integration at enterprise and commercial branch offices of all sizes and small-to-medium businesses. For more details about Wi-Fi 6, see Cisco’s technical white paper on Wi-Fi 6. Setup the RM 5400 Modem where you can get at least 2 Signal Strength lights are lit 5. Operating Temperature: 2 41 to 104°F (5 to 40°C) Operating Temperature , 3 (Short term) 4, 5 23 to 131° F (-5° to 55°C) for Cisco ASR 9006 Router, Cisco ASR 9906 Router, and Cisco ASR 9904 Router . 1. If port 1 is in the auto and on state and you configure it with a maximum wattage of 10 W, the switch removes power from the port and then redetects the powered device. Statement 1029 To replace the power supply in a Cisco 2901 router, perform the following steps. Product overview. System returned to ROM by power-on System restarted at 11:09:55 Sydney Wed Sep 24 2014. See Figure 5-3 for the locations of connectors and other components within the Cisco 2901 router. Connect the Power Supply and turn the power on. As of 2020, there are four Powers over Ethernet standards utilized by Cisco access points. AC power supply; 55 W to 145 W, 188 to 495 BTU/hr (configuration dependent) AC-POE power supply; 60 W to 330 W, 205 to 1126 BTU/hr (configuration dependent) Ports Console. 4. AC input frequency 47-63 Hz. Each downstream PHY module consumes approximately 70W of. Cryptographic Accelerator. Real-Time Clock. Hi Technical Team, We have one Cisco Catalyst 9300 Network Switch Model C9300-48-P with C9300-NM-8X and PWR-C1-715WAC-P/2 (Redundant power supply). Series. (4. The Cisco 2900 Series Integrated Service Routers comprise four platforms: the Cisco 2901, 2911, 2921, and 2951 ISRs with part numbers shown in Table 6. Motherboard Components Power consumption = 54. System Power Consumption. The Cisco 2901 ISR has an internal power supply, which requires removing the cover for replacement. With power measurement and policing, you can safely override the IEEE 802. AC input voltage:. A Cisco cBR-8 CCAP line card has two downstream PHY modules. Information About Reducing Power Consumption. 330W nominal/400W max. Options. Cisco 3845 HVSEC Bundle with IOS Advanced IP Services, PVDM2-64, AIM-VPN/SSL-3, 100 User SRST License, 25 User SSL VPN License, 512 MB Flash/1GB. A Cisco cBR-8 CCAP line card has two downstream PHY modules. Designed to support high 1/10/40/100 Gigabit densities in a 2RU form factor. Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetiCisco Intergrated Service Router ISR4331-V/K9 Voice bundle is ideally designed for the small to mid-size enterprise branch environment, delivers. 25 W. Beginner Options. Cisco Nexus 3408-S Switch Data Sheet (DOCX - 634 KB) Cisco Nexus 3000 Series Switches - Learn product details such as features and benefits, as well as hardware and software specifications. 3af power classification of a device that requires a power level at the lower end of its IEEE power classification range. Symptom - A fluctuating voice is when the volume of the voice increases and decreases in a wave fashion. RPS-enabled PoE boost. Step 7: show power. Brand: Cisco | Category: Network Router | Size: 4. SFP-10G-T-X. 72 Watts (53. These technologies allow you to meet increased endpoint power requirements without increasing the total power consumption of the branch. RPS Green System is running on external RPS power supply. We've seen part of the problem appears to be TCP ACKs delayed in a FIFO queue as we saw a huge jump when we implemented FQ on one side. pdf), Text File (. 4 watts). AC input current 2A (110V) 1A (230V) AC input surge current 50A maximum, one cycle (-48V power included) AC-IP maximum in-line power distribution 120W. Cisco has made a Power Consumption table, which shows different usage for different scenarios. Cisco 2901 datasheet power consumption The Cisco 2901 Integrated Services Router (ISR) delivers highly secure data, voice, video, and application services for small offices. Pls Rate if HELPS. Total System Power consumption is:. 85 Watts w/ 2 TCC, 2 XCVT, 1 AIC, 2 OC48 IR 1310 HS, 10 E100T-12 ANSI Chassis 1106. The first downstream PHY module has port number 0 through port number 3. initiatives, Cisco EnergyWise, Cisco Enhanced Power over Ethernet (ePoE), per-port PoE power monitoring, and. -division multiplexing (TDM) interconnections, and fully integrated power distribution to modules supporting 802. 3af Power over Ethernet (PoE) and Cisco Enhanced PoE;Table 3 lists power information for Cisco Catalyst 4500-X Series. The Cisco 2900 Series Module (ISM-VPN-29) can provide hardware-based IPSec encryption services of 145 and 550 Mbps in the Cisco 2901, 150 and 600 Mbps in the Cisco 2911, 220 and 700 Mbps in the Cisco 2921, and 385 and 900 Mbps in the Cisco 2951 (IPSec IMIX and 1400-byte packets). Cisco Catalyst® 2960-X, 2960-CX, and 3560-CX Series Switches reduce TOC in a unique way by lowering power consumption by up to 82 percent, with power usage reduced to 6. The VG320 and VG310 are built on the Cisco 2901 platform, powered by a single high-performance core processor. Key features include: CISCO2901/K9, a Cisco ISR G2 2900 Series Router.